Ramesh Sudini 910e80478d Disconnect ApnContexts in INITING state when error.
When DCT tears down a link due to error, the ApnContexts which are in INITING state are
not torndown. Due to this the DC refCount does not hit 0, and the Data Link is not torndown.

Bug: 4973894
Change-Id: If1263f360d55f6874220235fede294909db4837e
2011-07-07 16:35:52 -07:00
..