You can now use ALL and CURRENT when sending broadcasts, to specify
where the broadcast goes.
Sticky broadcasts are now correctly separated per user, and registered
receivers are filtered based on the requested target user.
New Context APIs for more kinds of sending broadcasts as users.
Updating a bunch of system code that sends broadcasts to explicitly
specify which user the broadcast goes to.
Made a single version of the code for interpreting the requested
target user ID that all entries to activity manager (start activity,
send broadcast, start service) use.
Change-Id: Ie29f02dd5242ef8c8fa56c54593a315cd2574e1c
Don't activate on sleep if below the threshold, and quit any currently
running dream when the threshold is reached.
Bug:6999949
Change-Id: I961b350d24ee6f95e502228aaa57312b0ffbadc1
bug: 6879638
- add new enum value BATTERY_PLUGGED_WIRELESS
- check for sys online file with contents "Wireless"
Change-Id: I22dc3c40f50573c98643e7b5cbcb237d0216530d
Now the dumpsys battery output will show up in bugreports again.
Change-Id: Id36e87d27e9d3c06dcc17671c81aa1d3fe260d1e
Signed-off-by: Mike Lockwood <lockwood@android.com>
Merge commit '13e46665ff69c1a37880762d7d611aacdf02dac7'
* commit '13e46665ff69c1a37880762d7d611aacdf02dac7':
Work on issue #3101415: Crespo apps seem to have their UID changed over time.
Merge commit 'd3e803ae28c369996f9acf6036ea99af5561949c' into gingerbread-plus-aosp
* commit 'd3e803ae28c369996f9acf6036ea99af5561949c':
Revert "Shutdown when capacity is 0% and no charging or when battery is dead"
This reverts commit fd04143a47770256dabcfa4d8447127b3ec8b2bf.
This break most automated tests because with this change, if the
device is fully charged, it will simply turn off the screen, regardless
if USB is connected to hsot PC or not; so for our tests, most of them
are always connected to host PC, and fully charged 99% of the time,
as soon as the screen turns off, the front-end test Activity will be
suspended.
Change-Id: I1e6590611af43812f1bac223dd31570d1d90cfc5
Merge commit 'fd04143a47770256dabcfa4d8447127b3ec8b2bf' into gingerbread-plus-aosp
* commit 'fd04143a47770256dabcfa4d8447127b3ec8b2bf':
Shutdown when capacity is 0% and no charging or when battery is dead
Android framework does not shutdown when battery capacity is 0% and a
charger is attached (USB or AC). This handling is incomplete since a
charger might very well be attached but charging has stopped because
USB suspended or the charging algorithm has stopped because of
battery safety handling. Also shutdown when battery is reported 'dead'.
This might happen although charging is present.
Change-Id: If328260ebf4d38f912e4d2fad204431cbb19c993
We now clear the battery stats when unplugging after the
battery is full. This allows us to use the "total" stats as
a new "since last charged" stat. Total is gone. I never used
it, it was worthless. Since last charged is a lot more
interesting.
The battery history now collects a lot more stats, and keeps
control over how much it can collect. Printing is now more
descriptive.
The kinds of stats have been renamed to SINCE_UNPLUGGED and
SINCE_DISCHARGED. The other two stats are still there, but
no longer printed; a future change will eliminate them
completely along with all of their state.
Change-Id: I4e9fcfcf8c30510092c76a8594f6021e9502fbc1
events (and in one case, a DropBox entry).
Add a simple intent that triggers master-clear (and toggle EFS), given the
right permissions.
Bug: 2264596
Bug: 2350452
Bug: 2264596
Use this in various places where it should serve no purpose to deliver
both broadcasts. This is intended to reduce somewhat the flurry of
broadcasts that we churn through during boot.
We can now locate event log tag definitions in individual packages
(and java constants for the tag numbers get auto-generated), so move
all the tags used by the system server into the package.
Also trigger low battery when battery reaches the specified level
rather than when it drops below the level.
Fixes bug b/1788656
Change-Id: I81f5cbb9892fc6574320d92e153211f83c69f415
Signed-off-by: Mike Lockwood <lockwood@android.com>
Wait until system is booted before attempting to display the shutdown dialog.
Use ShutdownActivity rather than attempting to run ShutdownThread in the battery service.
Fix logic error (check !isPowered() instead of isPowered())
Signed-off-by: Mike Lockwood <lockwood@android.com>
The "low" and "okay" broadcasts were not being sent with this flag, so that if
the device had booted in a low battery state, the battery service would crash
due to an illegal-state exception.
This fixes bug b/1985606
Two new broadcasts, Intent.ACTION_POWER_CONNECTED and
Intent.ACTION_POWER_CONNECTED, that are issued when the device is plugged
and unplugged from USB or AC power. This pulls two changes from the
open-source Gerrit repo into the internal Donut codeline:
1241 fda6fae Added broadcasts for external power events.
9491 37f8ca1 Fix system service crash when booting while on battery power
The current.xml API description has also been updated to include the
new Intent fields; the new API was approved in the original OSS change.
The usage stats service now collects per-activity launch time stats. There are a number of fixes and improvements to its statistics management and collection; it now operates its calendar in GMT and ensures that for checkin purposes it always reports one day and only one complete day to the checkin service.
Also change the checkin option from "-c" to "--checkin" since it is really a special thing.
2 levels as recorded at plug and unplug events. During charge cycles this would be useful because it would tell us
what the start and end levels were in the last discharge cycle. However during a discharge cycle this information could
be misleading as it would give you the level at the last unplug event (beginning the the discharge cycle) and last plug
event (end of the previous discharge cycle).
Now we are still keeping track of 2 values, but they are "discharge cycle start level" and "discharge cycle current level".
During a discharge cycle this will give you the level the current discharge cycle started at, and the current level. During
a charge cycle the same data will be supplied as before (the start/end of the last discharge cycle).
B=144249
Automated import of CL 144333