b/21187932
Made it an opaque class, since there is no need for a user to
inspect its fields after creation.
Change-Id: I9101afdecc5e25bb484d060be2a08c470faa92e5
b/21187932
Dependency from one kernel to another kernel -- where one reads the
other's output to a global allocation -- was not handled correctly.
This CL fixed that. Needed to make a new CTS test pass.
Change-Id: I500f9cac9d89bcaec7c186e942ba4a7d413daadb
bug 20822382
This corrects a copy&paste error placing F16 into F32.
Fixes an error disallowing vectors of fp16 types.
Change-Id: I34be1aa9a323d61a7121581ab9599d2c2d32dd42
Cherry-pick fix from AOSP. Error check for kernel launch was
generating a false positive.
bug 20690242
Change-Id: Ic4c6644072a11aab9a273070be5734519136f685
b/20728113
In case the requested size for memory allocation overflows, or memory
allocation fails.
Change-Id: I8dac132dd4d0210938660ffbb82cbe44000d2a90
(cherry picked from commit 4e90b9b57cc96964a9d5c1845172a72cb51feafb)
- Typo for validateUplo
- Typo in ZHEMM, element should be FLOAT64_2.
- For GEMM and SYMM, SYRK, 'CONJ_TRANSPOSE' should also be handled in the
validation process.
- For SYMM, check matrix A is symmetric.
- For HERK, the dimension validation was switched for Transpose case.
Also, only Conj Trans is allowed in this case.
- FOR SYR2K, fix the dimension check for Matrix C.
- For TRMM & TRSM, fix the validation part for dimension check.
Change-Id: I559b5c5695aa82604de2955ae2327b694236d3ed
And mark existing methods and builder deprecated.
Removed ScriptGroup2 class.
Renamed nested class UnboundValue to Input.
Marked classes Closure, Future, and Input as final.
Change-Id: I362910c115e9d0173dc515674e08bf4878232879
The name is not used in any meaningful way yet, but would be used
to name the file for generated code for fused kernels in other
coming CLs.
A script group name cannot be null or empty, or longer than 100
characters. It can only contain letters, digits, '-', or '_'.
Change-Id: I95fdbf58e6689da91ca98c2057dfa1a803d3b27b
The name is not used in any meaningful way yet, but would be used
to name the file for generated code for fused kernels in other
coming CLs.
A script group name cannot be null or empty, or longer than 100
characters. It can only contain letters, digits, '-', or '_'.
Change-Id: I95fdbf58e6689da91ca98c2057dfa1a803d3b27b
b/20032217
Some data types requires data alignment. This has an impact on the
total data size for the FieldPack. Fixed createFiledPack()
implementation to handle this correctly.
Change-Id: I241da19df69bf51cfdaf3b3a1381b446eaacb7fb